Product Description
Avalon / Lopi / FPX - Replacement Proflame LP Stepper Motor 250-01463
- Propane Gas Only
- Pressure out W.C: 11" - 2.9"
Cross Reference:
- Avalon: 250-01463
- Fireplace Xtrordinair - FPX (Travis Industries): 250-01463
- Lopi (Travis Industries): 250-01463
Installation:
Remove the control panel to access the gas control valve. The stepper motor (adjustable regulator) has an installation sheet included with it – make sure to follow all of the directions. Place the stepper motor on the gas control valve (see pictures below) – MAKE SURE IT IS CORRECTLY ORIENTED. Secure using the screws included with the motor – tighten to 25 Lb-inches. Leak test this area after installation to verify proper installation. NOTE: Install the identification label that is included with the conversion kit, to the valve body where it can be easily seen. 1
Restore the appliance to the correct configuration. Make the gas line connection, bleed the gas line (if applicable), start the heater and thoroughly leak-test all gas connections and the gas control valve